Asko H8 Especificaciones Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
25
rum Wa
2-4. How to Control Voltage (during abnormal operation)
1) Voltage Control
$ Normal Voltage
DC-link voltage after wave rectification is directly impressed to IPM as 310 ~ 330V.
When motor starts operation, DC voltage changes with energy consumed by motor and/
or counter electromotive force of motor.
% Identifying Abnormal Voltage
A. Occurrence of counter electromotive force
+ In case of 450V or higher
B. Instant power failure and excessive energy consumption
+ In case of 185V or lower
2-5. How to Control Current (during abnormal operation+B227)
1) Current Abnormality Detection
$ Abnormal if DC current flowing through IPM measured during high-speed motor rotation is
10A~12A or higher
% Detection of abnormal current to be carried out by saving higher value among instant current values
and updating the data
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 65 66

Comentarios a estos manuales

Sin comentarios